GX7
Power Amplifier
SPECIFICATIONS | GX3 | GX5 | GX7 | |||
Output power per channel | ||||||
8 ohms / 1 kHz (both channels driven) | 300 W | 500 W | 725 W | |||
8 ohms / 1 kHz (single channel driven) | 350 W | 600 W | 800 W | |||
4 ohms / 1 kHz (both channels driven) | 425 W | 700 W | 1000 W | |||
4 ohms / 1 kHz (single channel driven) | 500 W | 850 W | 1200 W | |||
Distortion (1 dB below rated power, 1 kHz) | 8 ohms: less than 0.02% 4 ohms: less than 0.05% | |||||
Signal to Noise (20 Hz - 20 kHz) | 100 dB | |||||
Input Sensitivity | 1.2 V rms | |||||
Voltage Gain | 32.2 dB | 34.4 dB | 36.1 dB | |||
Output Circuitry | Class B | 2-tier Class H | 2-tier Class H | |||
Power Requirements (1/8 power, pink noise at 4 ohms, 120V) | 6.3 A | 6 A | 10.1 A | |||
Frequency Response | 20 Hz–20 kHz, +0, -1 dB | |||||
Dynamic Headroom (4 ohms) | 2 dB | |||||
Input Impedance | Greater than 20 kΩ (balanced) | |||||
Maximum Input Level | +24 dBu (16 V rms) | |||||
Input Connectors (each channel) | 3-pin XLR and 1/4" TRS, balanced, parallel Phono, unbalanced | |||||
Output Connectors (each channel) | Speakon®, 1/4", Binding posts | |||||
Amplifier and Load Protection | Short circuit, open circuit, thermal, RF protection Load protected against DC faults | |||||
Front Panel Controls and Indicators | Gain controls, 21 detents Red CLIP LEDs, proportional, 0.1% THD threshold Green SIGNAL LEDs, threshold 35 dB below clipping Blue POWER LED, AC on | |||||
Rear Panel Controls | Full Range / Crossover switch 100 Hz, 3rd order LP (sub), 2nd order HP (top) | |||||
Dimensions | Height: 3.5" (89 mm) 2RU Width: 19" (483 mm) Depth: 10.1" (257 mm) | |||||
Weight | Net: 27 lb (12.1 kg) Shipping: 31 lb (14.1 kg) | Net: 28 lb (12.6 kg) Shipping: 32 lb (14.6 kg) | 120V model: Net: 15.5 lb (7 kg) Shipping: 20.5 lb (9.3 kg) 230V model: Net: 16.5 lb (7.5 kg) Shipping: 21.5 lb (9.75 kg) | |||
Agency Approvals | UL, CE, RoHS/WEEE Compliant | |||||
AC Current and Heating, 120 VAC (multiply current by 0.5 for 230 VAC) | GX3 | GX5 | GX7 | |||
Operating Condition | AC amps | BTU/hour | AC amps | BTU/hour | AC amps | BTU/hour |
Idle | 0.2 | 44 | 0.3 | 60 | 0.6 | 82 |
8 + 8 ohms, 1/8 power 1 | 4.1 | 904 | 3.3 | 734 | 6.7 | 1169 |
8 + 8 ohms, 1/3 power 2 | 6.1 | 1160 | 8.5 | 1456 | 13.3 | 1807 |
8 + 8 ohms, full power 3 | 9.75 | 1109 | 16.2 | 1891 | 26.5 | 2167 |
4 + 4 ohms, 1/8 power 1 | 6.3 | 1515 | 5.8 | 1160 | 10.1 | 1963 |
4 + 4 ohms, 1/3 power 2 | 9.4 | 2105 | 11.2 | 2162 | 18.5 | 2612 |
4 + 4 ohms, full power 3 | 15.0 | 2297 | 24.5 | 3754 | 40 | 4478 |
1 1/8 power represents typical maximum operating conditions
2 1/3 power represents over-driven program levels
3 Full power is breaker limited to short periods
For 230 V, multiply AC current by 0.5
For 100 V, multiply AC current by 1.25